Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual

Torque Limiting 12 Torque Limiting NOTE: The torque limiting feature covered in this section is likely to be eliminated for Tier 4 engines. Torque limiting, on a temporary basis, using the TSC1 message over the J1939 data link will still be available for Tier 4 engines. 12.1 Torque Limit Switch 12.1.1 Torque Limit Switch Operation The torque limit switch can be used to limit engine torque output. When the torque limit switch is closed to ground, then the ECU will limit torque to the programmed value. It is important to note that when the torque limit switch is closed to ground, the torque curve is not shifted down. Rather, the torque curve is truncated or chopped at the torque limit value.

Essentially, a flat spot is created in the torque curve. Engine Torque Limit Engine Torque Allowable Range of Torque Limit TEL Engine Speed (rpm) Maximum Rated Engine Speed High Idle 12.1.2 Torque Limit Switch Configuration One parameter must be configured in Cat ET prior to using torque limit switch. This parameter is Maximum Engine Torque Limit. Maximum engine torque limit default varies with each flash file. This parameter cannot be programmed to less than the torque available at the programmed TEL.

12.1.3 Torque Limit Switch Installation Torque Limit Switch P1/J1 ECU Negative Battery (1) Fabricated to length A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 79 7 Torque Limit Switch REQUIRED PARTS Part Number Description Qty N/A or N/A Toggle Switch (SPST, Momentary) or Toggle Switch (SPST) 1 9X-3402 Connector Socket 1 N/A Terminal 2 N/A 18 AWG Wire (1)