Engine Monitoring and Protection 15.1.4.3 Inlet Air Temperature Monitoring Installation No installation is required for inlet air temperature monitoring to function. 15.1.5 Coolant Level 15.1.5.1 Coolant Level Monitoring Operation The coolant level will be monitored if an optional coolant level sensor is installed. Coolant level is monitored to automatically protect the engine when the coolant level drops below a fixed level determined by the location of the sensor in the cooling system. The coolant level is checked for each ECU action level configured in the monitoring system for coolant level monitoring.
If the coolant level is below the minimum coolant level specified for the specified action level delay time, then the ECU takes the appropriate action to respond to the fault condition. The engine must be running at least 60 seconds before any fault condition is triggered. Once the fault is detected, the ECU illuminates the warning and diagnostic lamps and logs the appropriate event code from the following table for the action taken: The ECU can respond to the low coolant level condition with any or all of the following actions: Warning, Derate, and Shutdown. The ECU logs an event code and illuminates the lamps for all action levels.
The ECU will respond with the following additional actions when the monitoring system is configured to Derate or Shutdown: • Derate: Engine power is reduced to 35 percent below rated power over two seconds (at a rate of 17.5 percent/second). • Shutdown: The engine will shut down immediately. 15.1.5.2 Coolant Level Monitoring Configuration Two parameters can be configured in Cat ET to customize the monitoring system for coolant level monitoring. 1. ECU action for an event code defaults to “On” for Warning and Derate and “Off” for Shutdown. All actions can be configured to “On” or “Off.” 2. Time delay to take action defaults to 10 seconds for Warning, Derate, and Shutdown.
The time delay to take action on low coolant level event can be set within the range specified in the configuration table below. NOTE: The Time Delay for Warning, Derate, and Shutdown are triggered simultaneously. Notice in the table below, that as per Default Time Delays the engine will simultaneously begin Warning and Derate 10 seconds after the Coolant Level Switch changes state. If a customer desires a delay between Warning, Derate, and Shutdown, then the Derate and Warning Time Delay must be increased. For example, if Warning Time Delay is 10 seconds, Derate Time Delay is 20 seconds, and Shutdown Time Delay is 30 seconds.
Then the warning will occur 10 seconds after the Coolant Level Switch changes state. The Derate will occur 10 seconds after the Warning begins. Finally, the Shutdown (if turned ON) will occur 10 seconds after the Derate begins. The set point is determined by the coolant level sensor position, thus no configuration is required. The following table summarizes the configuration default settings and configuration ranges for low coolant level monitoring: Note: The engine must be running at engine speeds at or above low idle for 60 seconds before the above time delay is triggered.
A P P L I C A T I O N A N D I N S T A L L A T I O N G U I D E 99 Cat ET Description J1939 Description Status SPN FMI Low Coolant Level Coolant Level Warning 111 17 Derate 111 18 Shutdown 111 01 LOW COOLANT LEVEL MONITORING CONFIGURATION Action Default Value Time Delay (sec) Set Points Range Default Range Default Warning On 1 to 120s 10 N/A Derate On 1 to 120s 10 Shutdown Off 1 to 120s 10