Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT — Caterpillar C7 ACERT, C9 ACERT, C11 ACERT, C13 ACERT, C15 ACERT, C18 ACERT, C27 ACERT, C32 ACERT User Manual

Engine Monitoring and Protection The ECU can respond to the high inlet air temperature condition with any or all of the following actions: Warning and Derate. The ECU logs an event code and illuminates the lamps for all action levels. The ECU will respond with the following additional actions when the monitoring system is configured to Derate: • Derate: Engine power is reduced according to the inlet air temperature derate graph below. The power is reduced at a rate of one percent/second. The percent derate is a power reduction below the rated power curve.

Inlet Air Temperature Derate Graph (C7 ACERT & C9 ACERT Engines) Inlet Air Temperature Derate Graph (C11 ACERT - C32 ACERT Engines) Rated Rated -3% -3% Available Power -6% Available Power -6% -12% -9% -12% -9% -15% -15% -18% -18% -20% -20% 110 111 112 113 114 109 115 116 117 86 87 88 89 90 85 91 92 93 Inlet Air Temperature o C Inlet Air Temperature o C 15.1.4.2 Inlet Air Temperature Monitoring Configuration Two parameters can be configured in Cat ET to customize the monitoring system for inlet air temperature monitoring. 1. ECU action for an event code defaults to “On” for Warning and Derate. All actions can be configured to “On” or “Off.” 2.

Inlet air temperature maximum limit default is specific to the engine model and is defined in the configuration table below. The maximum temperature limit for warning and derate can be lowered within the range specified in the configuration table below. The time delay is defined by the factory and cannot be modified. The following table summarizes the configuration default settings and configuration ranges for high inlet air temperature monitoring: Note: Cat ET may allow the Derate Set Point Range to be programmed even though the chart above indicates that it is Not Programmable. If the set point in Cat ET is altered, this will only change the temperature at which an Event Code is logged.

The programmed value will NOT change the temperatures at which the engine actually takes action in Derate. Note: The engine must be running at engine speeds at or above low idle for 180 seconds before the above time delay is triggered. I N D U S T R I A L E N G I N E E L E C T R O N I C S 98 HIGH INLET AIR TEMPERATURE MONITORING CONFIGURATION Action Default Value Time Delay (sec) Set Points Range Default Range Default Warning On None 8 C7 ACERT/C9 ACERT 65° C to 90° C C11 ACERT-C32 ACERT 65° C to 82° C C7 ACERT/C9 ACERT 90° C C11 ACERT-C32 ACERT 82° C Derate On None 8 C7 ACERT/C9 ACERT 65° C to 110° C C11 ACERT-C32 ACERT 65° C to 86° C C7 ACERT/C9 ACERT 110° C C11 ACERT-C32 ACERT 86° C