ARMY TM 9-2815-256-24 AIR FORCE TO 38G1-96-2 MARINE CORPS TM 2815-24/5 FIGURE 3-36. Checking Brush Holder e. Using a multimeter, touch one probe to field winding end of brush and other one to bare surface of yoke body, refer to FIGURE 3-37. There should be no continuity. If there is continuity, field windings are grounded. Replace the yoke assembly. FIGURE 3-37. Checking Field Coils f. Using a multimeter, touch one probe to lead wire and other one to brush, refer to FIGURE 3-38. There should be continuity. If there is no continuity, field windings are open circuited. Replace the yoke assembly. 3-48