Komatsu — Measuring Coupler Dump Angle

If you are using the multi-function lever, move the work equipment lever to the RAISE position (a). Make sure that the work equipment lever is at the HOLD position (b) once the boom is at maximum height. OPERATION 6. Use the bucket control lever and tilt the coupler to the DUMP position (c). You can only measure the coupler dump angle with the coupler at maximum dump angle. Make sure that the bucket control lever is at the HOLD position (b) once the coupler tilts. If you are using the optional multi-function lever, move the work equipment lever to the TILT position (e). The work equipment lever must be at the HOLD position (b) once the coupler tilts. 7.

Set the work equipment lock lever (4) to the LOCK position (L) so that the work equipment levers cannot move. WA430-6 2-147