Komatsu — Precautions for Charging Battery

OPERATION Precautions for Charging Battery If you do not handle the battery correctly when charging it, there is danger that the battery may explode. Always follow the instructions in “Discharged Battery” on page 2- 181 and the instruction manual accompanying the charger. Observe the following rules. Do not use or charge the battery if the battery electrolyte level is below the LOWER LEVEL line. This may cause an explosion. Check the battery electrolyte level periodically and add distilled water to bring the electrolyte level to the UPPER LEVEL line. Set the voltage of the charger to match the voltage of the battery to be charged.

If the voltage is not selected correctly, the charger may overheat and cause an explosion. Connect the positive (+) charger clip of the charger to the positive (+) terminal of the battery. Connect the negative (-) charger clip of the charger to the negative (-) terminal of the battery. Set the charging current to 1/10 of the value of the rated battery capacity. When carrying out rapid charging, set it to less than the rated battery capacity. Be sure to fix the clips securely. If the charger current is too high, the electrolyte will leak or dry up; this may cause the battery to catch fire and explode.