Komatsu — Connecting Booster Cable

Starting Engine with Booster Cables OPERATION When starting the engine with a booster cable, follow these instructions. Precautions When Connecting or Disconnecting Booster Cable When connecting the cables, never contact the positive (+) and negative (-) terminals. When starting the engine with a booster cable, always wear safety glasses and rubber gloves. Be careful not to let the normal machine and the problem machine contact each other. This prevents sparks from generating near the battery which could ignite the hydrogen gas given off by the battery. Make sure that there is no mistake in the booster cable connections. The final connection is to the engine block of the problem machine.

Sparks will be generated when this is done, so connect to a place as far as possible from the battery. When disconnecting the booster cable, be careful not to bring the clips in contact with each other or with the machine body. Remark The size of the booster cable and clips should be suitable for the battery size. The battery of the normal machine must be the same capacity as the battery on the machine to be started. Check the cables and clips for damage or corrosion. Make sure that the cables and clips are firmly connected. Check that the work equipment lock lever and the parking brake on both machines are at the LOCK position. Check that all levers are in the NEUTRAL position.

Connecting Booster Cable To prevent damage to the electrical system, first turn the problem machine’s starting switch and battery disconnect switch (if applicable) to the OFF position, then turn the normal machine’s starting switch and battery disconnect (if applicable) to the OFF position. Take out the keys to the battery disconnect switch(es). Connect the booster cable as follows, in the order of the numbers marked in the diagram. 1. Connect the clip of booster cable (A) to the positive (+) terminal of battery (C) on the problem machine. 2. Connect the clip at the other end of booster cable (A) to the positive (+) terminal of battery (D) on the normal machine. 3.

Connect the clip of booster cable (B) to the negative (-) terminal of battery (D) on the normal machine. 4. Connect the clip at the other end of booster cable (B) to engine block (E) on the problem machine. WA430-6 2-183