Komatsu — Disconnecting Booster Cable

OPERATION Starting Engine Always check that the work equipment lock lever is set to the LOCK position, regardless of whether the machine is working normally or has failed. Check that all the control levers are at the HOLD or neutral position. 1. Make sure the clips are firmly connected to the battery terminals. If not, a spark may occur. 2. Turn the battery disconnect switch in the good machine to restore power. Start the engine of the good machine. 3. If the problem machine has a battery disconnect switch, turn the key to allow power to return. 4. Turn the starting switch of the problem machine to the START position and start the engine.

If the engine does not start at first, wait for at least two minutes before trying again. Disconnecting Booster Cable After the engine has started, disconnect the booster cables in the reverse order in which they were connected. 1. Remove the clip of booster cable (B) from engine block (E) on the problem machine. 2. Remove the clip of booster cable (B) from the negative (-) terminal of battery (D) on the normal machine. 3. Remove the clip of booster cable (A) from the positive (+) terminal of battery (D) on the normal machine. 4. Remove the clip of booster cable (A) from the positive (+) terminal of battery (C) on the problem machine. 2-184 WA430-6