Komatsu — Clean Inside of Cooling System

Graphic for poor fuel arrangement specification MAINTENANCE 3. Check that the surface of the radiator cap is cool enough to be touched by hand. 4. Turn the radiator cap (2) slowly until it contacts the stopper to release the pressure. 5. Push radiator cap (2) further; turn it until it contacts the stopper; then remove it. 6. Put a container under the radiator to catch the coolant. 7. Open drain valve (3), at the left side of the fuel tank and drain the water. 8. Close drain valve (3) and fill the radiator with water. 9. Start the engine and run it at low idle. Keep the engine running at low idle for ten minutes until the coolant temperature reaches more than 90°C (194°F). 10.

Stop the engine; open drain valve (3); drain the water; then tighten the drain valve again. 11. Clean the cooling system with the cleaning agent. Follow the instructions provided with the cleaning agent. 12. Replace the corrosion resistor cartridge, then open the two valves (1). For details about replacing the corrosion resistor, see “Replace Corrosion Resistor Cartridge (Standard Specification)” on page 3-78 or “Replace Corrosion Resistor Cartridge (Poor Fuel Arrangement Specification)” on page 3-78. 13. Add the coolant and water mix through the water filler port until it overflows.

To determine the mixing ratio for the antifreeze and water, see “Water and Supercoolant Mix Ratio Table” on page 3- 34. WA430-6 3-35