MAINTENANCE Using Compressed Air Steam or water can be used instead of compressed air. Never open the engine side cover when the engine is running. Stop the engine completely before starting the cleaning operation. 1. Insert a jet nozzle through the gaps between the radiator, oil cooler, aftercooler (1), and air conditioner condenser (2). When cleaning the face behind the radiator, or oil cooler, and aftercooler (1), remove bolt (4) and plate (3), then insert the jet nozzle through the opening to clean the fins. If the steam jet nozzle is brought too close to the radiator fins, it may damage the fins. Keep the nozzle a suitable distance away from the fins when cleaning. 2.
Work under the following rough conditions: Injection pressure: . . . . . . . . . . . . . . . . . . Max. 9.8 MPa (1420 psi) Nozzle diameter: . . . . . . . . . . . . . . . . . . . . . . . .Max. 2 mm (0.1 in) Distance between nozzle and radiator fins: . . Min. 100 mm (3.9 in) 3. Inspect the rubber hoses. If any hose is cracked or deteriorated, replace it. 4. Check that there are no loose hose clamps. 3-44 WA430-6