Komatsu — Check Air Conditioner

MAINTENANCE 7. Use sight glass (6) (inspection window) of receiver drier (5) to check the condition of the refrigerant gas (freon 134a) flowing in the refrigerant circuit. Schedule for Maintenance and Inspection When Not Using the Air Conditioner Regularly To prevent leakage of the refrigerant from the air conditioner cooling circuit, operate the air conditioner for several minutes two or three times a month during the off-season. If the air conditioner is left for a long time when the refrigerant is leaking, it may cause internal rust.

Run the air conditioner in cooling or dehumidification plus heating mode for several minutes from time to time to prevent the loss of the oil film in various parts of the compressor. If the temperature inside the cab is low, the air conditioner may not work. In such cases, use the recirculated air to warm up the inside of the cab, then turn the air conditioner switch on. 3-50 WA430-6 A: Quantity of Refrigerant B: Condition of Sight Glass a Proper After air conditioner switch is turned ON, few bubbles are seen and refrigerant becomes milk-white and then becomes pale milk-white. b Insufficient refrigerant After air conditioner switch is turned ON, bubbles are seen continuously. X:

Condition of Refrigerant Flow Y: Condition of Sight Glass x There are bubbles. Gas and liquid of refrigerant are mixed. y There are no bubbles. All refrigerant is liquefied and transparent. z Refrigerant is milk-white. Oil and refrigerant are separated from each other and their mixture is pale milk-white. Inspection Location Item to Check Maintenance Interval Check before Operating 6 Months Replacement Interval Filter Clogging, dirt Carry out check – 2 years Condenser Clogging, dirt Carry out check – – Belt Looseness, damage Carry out check – 2 years Refrigerant gas Amount – Carry out check – Piping Looseness, damage, leakage – Carry out check – Receiver drier – – – 2 years