Procedure for Bleeding Air MAINTENANCE 1. Fill the fuel tank with fuel. 2. Insert the key in the starting switch and turn it to ON position (B). 3. Hold the key at the ON position (B) for 30 seconds, then return it to OFF position (A) and wait for ten seconds. 4. Repeat the operations in Step 2 and Step 3 four times. 5. Crank the engine with the starting motor (starting rotation of starting motor) and start the engine. When the engine is cranked, the air is automatically bled from the high-pressure circuit. If the engine does not start, the air has probably not been bled properly from the low-pressure circuit. Repeat the procedure from Step 1.
If the engine is operated with air remaining in the fuel circuit, an error (AC449), CA559) may be generated in the fuel system. If this happens, keep the throttle at Lo after starting the engine and run the engine continuously for approximately three minutes. When the air is bled and the engine rotation becomes stabilized, the error display will go out. WA430-6 3-71