OPERATION LONG TERM STORAGE DURING STORAGE 3 When it is necessary to perform the rust-preventive operation while the machine is indoors, open the doors and windows to improve ventilation and prevent gas poisoning. q During storage, always operate the machine once a month so that a new film of oil will be coated over mov able parts and component surfaces. At the same time, also charge the battery. q When operating the work equipment, wipe off all the grease from the hydraulic cylinder rod. q If the machine is equipped with an air conditioner, operate it for 3 to 5 minutes once a month to lubricate each portion of its compressor. Be sure to idle the engine at low speed for this purpose.
Also, check the quantity of refrigerant twice a year. AFTER STORAGE 3 NOTICE If the machine has been stored without the monthly rust prevention operation, consult your Komatsu dis tributor for service. When using the machine after long-term storage, do as follows before using it. q Wipe off the grease from the hydraulic cylinder rods. q Add oil and grease at all lubrication points. q When the machine is stored for a long period, moisture in the air can contaminate the oil over time. Check the oil for presence of water before and after starting the engine. If there is water in the oil, change the oil. q A plastic fuel tank is used, so never use trichloroethylene when washing it.
Washing in trichloroethylene will reduce the strength of the fuel tank. 3-105 WARNING