Komatsu — CLEAN INSIDE OF COOLING SYSTEM

MAINTENANCE PROCEDURE MAINTENANCE 4. Place a container to catch the coolant under the drain hose installed to drain valve (2) and under coolant drain plug (3) on the engine block. 5. Open drain valve (2) and drain the water. Remove drain plug (3) from the engine cylinder block and drain the water. 6. After draining the antifreeze solution, close drain valve (2) and tighten drain plug (3), then fill with clean water. After the radiator is filled with water, start and run the engine at low idling speed. After the water temperature rises above 90°C (194°F), run the engine for about 10 minutes. 7. Stop the engine, then open drain valve (2) and remove drain plug (3) to drain the water. 8.

Close drain valve (2). Wind seal tapes onto drain plug (3), then tighten it. 9. Decide the proportions of antifreeze and water according to the table for the mixing rate of water and anti­ freeze. 10. After the engine warming up, check that each gauge and caution lamp are in normal condition. If any abnor­ mality is found, carry out adjustment or repairs. Operate the machine under a light load until the engine water temperature gauge (2) points to the white range (monitor panel spec.) or the green range (gauge panel spec.). To remove the air in the coolant, run the engine for 5 minutes at low idling, then for another 5 minutes at high idling.

(While doing this, leave the radiator cap removed) 11. Drain the cooling water inside sub-tank (4), clean the inside of the sub-tank, then fill again with cooling water to a point midway between the FULL and LOW marks. 12. Stop the engine. About 3 minutes later, supply city water up to the water filler, then close radiator cap. 4-24