ATTACHMENTS AND OPTIONS AIR CONDITIONER Every 500 Hours Maintenance 6 Clean Air Conditioner Condenser If compressed air, high-pressure water, or steam hit your body directly, or they cause dirt or dust to be blown up, there is a hazard of serious injury. Always use safety glasses, dust mask, or other protective equipment. NOTICE When using compressed air, keep the air nozzle at a distance to prevent damage to the fins. Especially for the aftercooler, blow the air from 300mm (11.8 in) or more, and at a 45 degree angle. To prevent damage to the fins, apply compressed air from an appropriate distance. Damaged fins may cause water leakage or overheating.
On dusty sites, check the fins daily, regardless of the maintenance interval. 1. Blow off mud, dust or leaves clogging the condenser fins using compressed air. Steam or wter may be used instead of compressed air. 2. Check the rubber hose. Replace with a new one if the hose is found to have cracks or to be hardened by ageing. Also, check hose clamps for looseness. 6-9 WARNING