puls — Puls 1106 Series Marine Propulsion Engines User's Handbook

N40469 Chapter 5 How to drain the auxiliary water system Caution: The auxiliary water system cannot be drained completely. If the system is drained for engine preservation purposes or for protection from frost, the system must be filled again with an approved antifreeze mixture. 1. Ensure that the seacock is closed (figure 4 item 1). 2. Remove the drain plug (figure 5 item 1), from the gearbox oil cooler. Ensure that the drain hole is not restricted. Figure 4 3. Turn the crankshaft to ensure that the auxiliary water pump is empty. 4. Fit the drain plug to the gearbox oil cooler. Caution: When the auxiliary water system is to used again, ensure that the seacock is open. Figure 5 Page 29