Chapter 5 N40469 How to check the impeller of the auxiliary water pump Caution: When the impeller is checked, the strainer in the outlet hose of the auxiliary water pump must also be checked. 1. Ensure that the seacock is closed. 2. Release the four bolts (items 1 figure 6) which fasten the end plate of the auxiliary water pump and remove the plate. When the end plate of the auxiliary water pump is removed, some auxiliary water will flow from the pump. 3. Care should be taken with the sealing ‘O’ ring (item 1 figure 7). 4. Remove the rubber end cap (item 2 figure 7) and then pull the impeller from the shaft (figure 8). 5.
Clean the contact surfaces of the pump body and Figure 6 the end plate. 6. Inspect the rubber impeller for excessive wear or for damage and renew it, if necessary. 7. Apply Spheerol SX2 grease to the blades of the new impeller and fit the impeller into the housing with the blades bent clockwise. Refit the rubber end cap and sealing ‘O’ ring. 8. Fit the end plate and tighten the end plate bolts. 9. Open the seacock. Figure 7 Figure 8 Page 30