DD Platform EuroIV Operators Manual Table 7. Water Requirements Distilled, reverse osmosis-purified, or de-ionized water which eliminates the adverse effects of minerals in tap water is preferred. High levels of dissolved chlorides, sulfates, magnesium, and calcium in some tap water causes scale deposits and/or corrosion resulting in water pump failures and poor heat transfer, leading to overheating. If tap water is used, the mineral content in the water must be below the following maximum allowable limits. Table 8. NOTICE: Do not add additional supplemental coolant additives to new, fully formulated antifreeze or coolant. This can result in dropout and/or the formation of deposits.
Coolant Maintenance Intervals Check the nitrite concentration at the regular intervals listed in the following table with a Detroit Genuine Fluid Analysis 3–Way Test Strip. All information subject to change without notice.
95 DDC-SVC-MAN-0175 Copyright © 2014 DETROIT DIESEL CORPORATION Fully Formulated Glycol Coolant Concentration Limits with TMC RP-329 Chemistry Type A (50/50 Coolant/Water Mixture) Boron 125 – 500 PPM Nitrite 900 – 3200 PPM Nitrate 200 – 1000 PPM Silicon 50 – 150 PPM Phosphorous 0 PPM pH 8.0 – 11.0 Satisfactory Water Limits – Make-Up Water Only Maximum Allowable Parts per Million Grains per Gallon Chlorides 40 2.5 Sulfates 100 5.8 Total Dissolved Solids 340 20 Total Hardness – Magnesium and Calcium 170 10