Preventive Maintenance Intervals 1. Water in Fuel Separator(Coalescer/ Final Filter) Cap 2. Pre Filter Cap 3. Water Drain Valve Figure 14. Fuel Filter Module Fuel Filters The prefilter is housed within the fuel filter module. The prefilter element filters particles down to 100 microns and is snapped into the prefilter cap. The coalescer/ final filter is housed within the fuel filter module. The coalescer/final filter has the task of separating out the water contained in the fuel and also filtering out particles down to 3 to 5 microns. The coalescer/final filter snaps into the coalescer/final filter cap.
Air System Air Cleaner - The air cleaner element should be inspected per the maintenance intervals or more often if the engine is operated under severe dust conditions. Replace the element, if necessary. Check the gaskets for deterioration and replace, if necessary. If the dry type air cleaner is equipped with an aspirator, check for aspirator damage or clogging. Clean, repair or replace, as necessary. NOTICE: Do not allow the air inlet restriction to exceed 5.5 kPa (22 in. H2O) under any engine operating conditions.
A clogged air cleaner element will cause excessive intake restriction and reduced air supply to the engine resulting in increased fuel consumption, inefficient engine operation and reduced engine life. 72 All information subject to change without notice. Copyright © 2019 DETROIT DIESEL CORPORATION DDC-SVC-MAN-0209