Yamaha Motor Co., Ltd. VK540E — Yamaha Motor Co., Ltd. VK540E User Manual

3. Check: Specific gravity Less than 1.280 Recharge battery. Charging current: 1.4 amps/10 hrs Specific gravity: 1.280 at 20 C (68 F) Replace the battery if: Battery voltage will not rise to a specific value or if bubbles fail to rise even after many hours of charging. Sulfation of one or more cells occurs, as indi- cated by the plates turning white, or if an accu- mulation of material exists in the bottom of the cell. Specific gravity readings after a long, slow charge indicate one cell to be lower than the rest. Warpage or buckling of plates or insulators is evident. CAUTION: Always charge a new battery before using it to ensure maximum performance. 4. Install:

Battery Battery holder CAUTION: Connect the positive lead 1 first and then connect the negative lead 2 . 2-29 BATTERY INSPECTION INSP ADJ