FUSE INSPECTION 1. Remove: Fuse 1 Spare fuse 2 2. Inspect: Fuse Inspection: Connect a pocket tester to the fuse and check it for continuity. NOTE: Set the tester selector to “ Ω 1” position. If the tester indicates the fuse is blown. It must be replaced. 3. Replace: Blown fuse Replacement steps: Turn off the ignition and the circuit. Install a new fuse of proper amperage. Turn on the switches to verify operation of the electrical device. If the fuse blows again immediately, check the circuit in question. NOTE: Install new fuses of proper amperage. WARNING Do not use fuses of higher amperage rating than that which is recommended.
Extensive electrical system damage and fire could re- sult from the substitution of a fuse of im- proper amperage. 2-30 FUSE INSPECTION INSP ADJ Pocket tester: 90890-03112, YU-03112 Description Amperage Quantity Main 10A 1 Spare 10A 1