Kubota — B Adjusting Air-Conditioner Belt Tension

87 PERIODIC SERVICE B Checking Air Conditioner Condenser Check air conditioner condenser to be sure it is clean of debris. B Adjusting Air-Conditioner Belt Tension 1. Push on the belt between the pulleys with a finger. A deflection of 10 to 12 mm under a 98 N (10 kgf) load is appropriate. 2. If tension is incorrect, loosen the tension pulley mounting nut and turn the adjusting bolt to adjust the belt tension within acceptable limits. (1) Air conditioner condenser C Sliding the air conditioner condenser To avoid personal injury: A The condenser and receiver become hot while the air conditioner is running. Before checking or cleaning them, wait long enough until they cool down.

(1) Adjusting bolt (2) Tension pulley mounting nut (A) 10 to 12 mm 1. Release the air conditioner hoses off the hook. 2. Loosen the wing nut. 3. Hold the handle, slide the air conditioner condenser assembly toward yourself. (1) Condenser (2) Receiver (3) Handle (4) Wing nut (5) Air conditioner hose (6) Hook (A) "PULL" A Do not hold the air conditioner receiver or the air conditioner pipes when sliding out the condenser for cleaning.