Kubota — B Positions and advantages of the flow control valve

47 HYDRAULIC UNIT B Adjusting the flow rate To avoid the possibility of personal injury or death be aware of the following when making adjustments: A The 3-point hitch operation is influenced by the combination of the adjustment of the flow control valve and the engine speed. A The 3-point hitch may rise slowly or not at all at low engine rpm. A The 3-point hitch may rise suddenly if engine rpm is increased, or, flow control adjustment is changed. (1) Remote control valve (1) (2) Remote control valve (2) (3) Remote control valve (3) (4) Flow control valve (5) Flow control knob (A) "INCREASE" (B) "DECREASE" (C) "STOP" Refer to the illustration below. 1.

The flow rate for the remote control valves (2) or (3), located on above the flow control valve (4), can be adjusted. 2. Turn the flow control knob (5) counterclockwise (A), and the flow rate for the remote control valves (2) or (3) increases. A clockwise turn (B) of the knob causes the flow to decrease. If the knob is turned all the way (C), there will be no flow. 3. To adjust the flow rate, set the engine speed to the operating RPM, turn the flow control knob once all the way clockwise (C), and then turn it gradually counterclockwise until a required flow rate is reached. B Positions and advantages of the flow control valve Refer to illustration below. C Position 1 1.

The attachment control speed (hydraulic motor RPM, for example) of the remote control valve (1) can be maintained at a constant level within limits. 2. The remote control valve (1) and the 3-point hitch can be operated at the same time. The 3-point lift speed will be influenced by the level of flow required at remote control valve (1). A Full adjustment of the valve will occur in approximately 1 1/2 revolutions of the flow control knob. Turning the flow control knob beyond this point will have no affect on the flow rate. A When there is no need to adjust the flow rate, turn the flow control knob all the way counterclockwise and keep it in this position.

(1) Remote control valve (1) (2) Flow control valve