COMPONENT OPERATION / Control Valve RESTRICTION VALVE The restriction valve is installed at the inlet part to the pilot circuit on the both ends of the spool for the lift arm. If the pilot valve is tuned to the neutral position during operation of the lift arm, the pilot pressure oil supplied to the spool for the lift arm is drained through the orifice of the check valve of the restriction valve. Thereby, pilot pressure gradually decreases. Therefore, shock to the body occurring during operation of the front attachment can be reduced by gradually returning the lift arm spool to the neutral position. Check Valve Orifice Spool Side Pilot Valve Side T4GB-03-02-014 T3-2-19