hitachi — Negative Control Valve

COMPONENT OPERATION / Control Valve NEGATIVE CONTROL VALVE The control valve has a built-in negative control valve. The negative control valve controls delivery flow of the main pump by flow rate control pressure (Pc1 and Pc2). Operation Negative Control Valve Orifice Pc2 Pc1 In Neutral Pressure oil through the control valve neutral circuit with the control valve in neutral position is supplied as pilot pressure for controlling the pump delivery flow from the front and rear of the orifice of the negative control valve installed at the outlet of the control valve. At this time, spool B moves to the left as the differential pressure occurs between Pc1 and Pc2.

Therefore, pilot pressure (PS2) enters the large diameter chamber in the servo piston through spool B and spool A. Pilot pressure (PS2) also enters the small diameter chamber in the servo piston. As the large diameter chamber is larger than the small diameter chamber, the servo piston moves to the right and the pump delivery flow is reduced. In Operation During operation of the lift arm and the bucket, pressure oil is not supplied to Pc1 and Pc2. At this time, as the differential pressure between Pc1 and Pc2 disappers, the regulator in the main pump is in neutral and the delivery flow is not restricted (the pump delivery flow increases).

Main Pump Neutral Circuit Servo Piston Large Diameter Chamber Small Diameter Chamber Spool A T4GB-03-02-015 Spool B T3-2-20 Pilot Pr (PS2) essure