Terex TL160 — 8.2 Table of faults

Trouble-shooting 8 Tab. 31 Table of faults 108/112 TL160 Operating Manual 12.9.08 Version 1.0 Possible cause Remedy Decrease in machine's performance (loader installation) Insufficient engine power Check diesel engine and adjust if necessary Hydraulic oil level too low Top up hydraulic oil to mark on dipstick Pump is sucking up air Re-tighten hose connections.

Replace O-ring or seals Insufficient operating pressure Re-adjust main pressure relief valve, replace if necessary Pump worn Replace pump Incorrect hydraulic oil Quality of hydraulic oil must conform to our recommendation Working cylinders are not working satisfactorily Seals in cylinders worn Re-seal cylinders Secondary valves damaged Check secondary valves and replace completely if necessary Faults in the electrical system Outside and/or internal lighting damaged Check cables, connections, bulbs and fuses Windshield wiper not working Check cables, connections, and fuses Examine windshield wiper for mechanical damage, replace if necessary Horn not responding Check cables, connections, and fuses Replace complete horn if required Control organs are imprecise Determine the fault or source of the problem, call Service Agent if necessary Starting system does not work satisfactorily Check charge capacity of battery Test starter function Check connection and condition of power and battery ground cables Check function of ignition lock, replace if necessary