Terex TL160 — 7.8.6 Air filter, air intake

Care and Maintenance 7 7.8.6.5 Changing the main cartridge Release the wire fasteners (56/1) and remove the bottom of the housing (56/4). Withdraw the main cartridge (56/2) by twisting slightly to and fro. Check whether the safety cartridge (56/3) must be replaced. Attention Remove the safety cartridge only in the case of necessary maintenance work. Only open the seal (56/ 5) of the safety cartridge for the purpose of replacement. Note down the date of maintenance in the appropriate sections of the safety cartridge (56/3). Insert the new or cleaned main cartridge carefully into the filter housing starting with the open side and check that it is correctly positioned.

Fit the lower part of the housing. (Pay attention to the position of the dust ejection valve). Place the wire fasteners in the groove of the flange on the filter housing and tighten. 7.8.6.6 Changing the safety cartridge Remove the main cartridge. Machine damage due to damaged safety cartridge. Observe that the safety cartridge must not be cleaned and used again once it has been removed. Using a suitable tool (e. g. screwdriver), pierce the seal (56/5) of the safety cartridge (56/3) from the inside, then lift up the two clips (56/6). Fig. 56 Changing air filter cartridges Grasp the safety cartridge (56/3) by the two clips (56/6), withdraw by twisting slightly to and fro, and dispose of it.

Insert a new safety cartridge and check that it is correctly positioned. Re-install the main cartridge. 85/112 TL160 Operating Manual 12.9.08 Version 1.0 1. 1 2. 4 3. 2 3 5 6 L86354