Terex TL160 — 7.8.6 Air filter, air intake

Care and Maintenance 7 7.8.6.7 Cleaning the main cartridge Machine damage due to damaged main cartridge. Never wash or brush out the main cartridge. When blowing out, ensure that no dust enters the inside of the main cartridge. The main cartridge can be cleaned up to five times if necessary. It must be replaced once it reaches its maximum service life of two years, at the latest. The number of times it is cleaned must be marked. For cleaning (57/1), a pipe the end of which is bent at 90° should be attached to a compressed-air pistol. It must be sufficiently long to reach the floor of the cartridge. Blow out the main cartridge from the inside to the outside with dry compressed air (max.

5 bar) by moving the pipe up and down in the cartridge and continue until no more dust escapes. Check the clean main cartridge for damage to the paper bellows and rubber seals (57/2). Tears and perforations in the paper bellows can be determined using a torch. Machine damage due to damaged main cartridge. Never continue to use damaged main cartridges. If in doubt, use a new one. 86/112 TL160 Operating Manual 12.9.08 Version 1.0 1 max. 5 bar 2