Cooling System QSB4.5 and QSB6.7 Page 7-6 Section 7 - Maintenance Procedures at 2000 Hours or 2 Years Fill The system must be filled properly to prevent air locks. During filling, air must be vented from the engine coolant passages. Wait 2 to 3 minutes to allow air to be vented; then add mixture to bring the level to the top. CAUTION To be sure air is vented during the fill process: The thermostat has check balls that allow air to vent through the thermostat when the thermostat is closed. A deaeration port is located next to the water outlet connection which connects to the top tank/coolant recovery tank of the cooling system.
The system has a design fill rate of 19 liters [5 gal.] per minute. Never use water alone for coolant. Damage from corrosion can be the result of using water alone for coolant. CAUTION Use a mixture of 50-percent water and 50-percent ethylene glycol or propylene glycol antifreeze to fill the cooling system. Refer to the Cummins Coolant Requirements and Maintenance, Bulletin 3666132, for engine coolant specifications. For cooling system capacity, refer to Procedure 018-018 (Cooling System) in Section V. WARNING Do not remove the pressure cap from a hot engine. Wait until the coolant temperature is below 50°C [122°F] before removing the pressure cap.
Heated coolant spray or steam can cause personal injury. Install the pressure cap. Operate the engine until it reaches a temperature of 80°C [180°F] and check for coolant leaks. Check the coolant level again to make certain the system is full of coolant or that the coolant level has risen to the hot level in the recovery/expansion tank in the system, if so equipped.