QSB4.5 and QSB6.7 Overhead Set Section 8 - Maintenance Procedures at 5000 Hours or 4 Years Page 8-1 Maintenance Procedures - Overview General Information All maintenance checks and inspections listed in previous maintenance intervals must also be performed at this time, in addition to those listed under this maintenance interval. Overhead Set Preparatory Steps WARNING Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last. Disconnect the batteries.
Refer to the original equipment manufacturer (OEM) service manual. Remove Wear appropriate eye and face protection when using compressed air. Flying debris and dirt can cause personal injury. WARNING Prior to removing any components, use compressed air to remove any loose debris from around the mounting fasteners and sealing joints.