Cummins — 4021531

Overhead Set QSB4.5 and QSB6.7 Page 8-2 Section 8 - Maintenance Procedures at 5000 Hours or 4 Years Disconnect the breather tube connection at the back of the rocker lever cover. In general, two types of breather tube connections are used at the rocker lever cover: A clamping plate and capscrew hold the breather tube connection to the rocker lever cover. Remove the capscrew and clamping plate to disconnect the breather tube connection from the rocker lever cover. One or two capscrew(s) directly mount the breather tube connection to the rocker lever cover. Remove the capscrew(s) to disconnect the breather tube connection from the rocker lever cover. NOTE:

Some breather tube connections use internal Torx™ capscrews to secure the breather tube connection to the rocker lever cover. If equipped, at the rear of the rocker lever cover, remove the banjo bolt and sealing washers connecting the breather oil drain line to the rocker lever cover. NOTE: Not all engines with an internal mounted crankcase breather are equipped with an external breather oil drain line. On some engines the breather oil drain line is internal to the breather connection tube (1). NOTE: Do not remove the rocker lever gasket on engines in which the rocker lever cover gasket is fit into a groove at the base of the rocker lever cover. The gasket is reusable.

Once the gasket is removed from the rocker lever cover, it must be replaced. Remove the mounting nuts and isolators from the rocker lever cover. NOTE: If equipped, it may be necessary to gently pry the breather tube connection from the back of the rocker lever cover while removing. Remove the rocker lever cover.