Overhead Set QSB4.5 and QSB6.7 Page 8-6 Section 8 - Maintenance Procedures at 5000 Hours or 4 Years If equipped, at the rear of the rocker lever cover, install the banjo bolt and sealing washers connecting the breather oil drain line to the rocker lever cover. Torque Value: 12 N•m [ 106 in-lb ] Not all engines with an internal mounted crankcase breather are equipped with an external breather oil drain line. On some engines the breather oil drain line is internal to the breather connection tube (1). Prior to connecting the breather connection tube to the rocker lever cover, apply clean engine oil to the o-ring located on the breather tube connection.
Connect the breather tube connection to the rocker lever cover. In general, two types of breather tube connections are used at the rocker lever cover: A clamping plate and capscrew hold the breather tube connection to the rocker lever cover. Install the capscrew and clamping plate to connect the breather tube connection to the rocker lever cover. One or two capscrew(s) directly mount the breather tube connection to the rocker lever cover. Install the capscrew(s) to connect the breather tube connection to the rocker lever cover. Tighten the Capscrew(s). Some breather tube connections use internal Torx™ capscrews to secure the breather tube connection to the rocker lever cover. Torque Value:
10 N•m [ 89 in-lb ]