Cummins — 4021531

Alternator QSB4.5 and QSB6.7 Page A-6 Section A - Adjustment, Repair, and Replacement Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To avoid arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last. WARNING WARNING Acid is extremely dangerous and can damage the machinery and can also cause serious burns. Always provide a tank of strong soda water as a neutralizing agent when servicing the batteries. Wear goggles and protective clothing to reduce the possibility of serious personal injury. Shut off the engine, and remove the test equipment.

Connect all battery cables, negative (-) cable last. Preparatory Steps WARNING Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last. Acid is extremely dangerous and can damage the machinery and can also cause serious burns. Always provide a tank of strong soda water as a neutralizing agent when servicing the batteries. Wear goggles and protective clothing to reduce the possibility of serious personal injury. WARNING Disconnect the batteries. Refer to the OEM service manual.

Remove the drive belt from the alternator pulley. Refer to Procedure 008-002 in Section A. Tag and label all wires on the alternator. Disconnect the wires. Remove Spool Mount Remove the upper alternator link capscrew. Remove the mounting capscrew and nut at the bottom of the alternator and the alternator mounting bracket. Remove the alternator.