QSB4.5 and QSB6.7 Alternator Section A - Adjustment, Repair, and Replacement Page A-5 Connect a carbon-pile load (battery/alternator tester) across the batteries in one of the battery boxes. Clamp an induction pickup-type ampere-hour meter around the battery cable; or use the digital multimeter, Part Number 3164488 or 3164489, with the clamp-on current probe, Part Number 3164490. WARNING Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last.
WARNING Acid is extremely dangerous and can damage the machinery and can also cause serious burns. Always provide a tank of strong soda water as a neutralizing agent when servicing the batteries. Wear goggles and protective clothing to reduce the possibility of serious personal injury. Disconnect any cables that lead to any other battery boxes in the circuit, negative (-) cables first. Operate the engine at high idle; and measure the alternator voltage output to the batteries with digital multimeter, Part Number 3164488 or 3164489. Refer to the OEM specifications.
Operate the engine at high idle and adjust the carbon-pile load-testing equipment to apply the maximum rated amperage load to the alternator. Refer to the OEM specifications. NOTE: The alternator maximum rated amperage output is normally stamped or labeled on the alternator. Measure the alternator amperage output. Refer to the OEM specifications. If the alternator output (amps) is not within 10 percent of rated output, repair or replace the alternator. Refer to the OEM service manual for repair procedures.