QSB4.5 and QSB6.7 Starting Motor Section A - Adjustment, Repair, and Replacement Page A-23 Cummins® Branded Starters Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last. WARNING Do not overtighten the electrical connections. Starter damage can result. NOTE: Use the location tags to help identify where each wire connection goes. CAUTION Connect the electrical connections to the starter motor. Torque Value: M5 Step 1 4 N•m [ 35 in-lb ] Torque Value:
M10 Step 1 21 N•m [ 185 in-lb ] Install the jump start protection (JSP) cover and nut on the M terminal post. NOTE: The JPS cover nut is the third nut on the M terminal, M5 terminal size. Failure to observe the proper torque specification can result in loss of conductivity to the M lead and result in a no crank condition for the starter and engine. Non-Cummins® Branded Starters Do not overtighten the electrical connections. Starter damage can result. NOTE: Use the location tags to help identify where each wire connection goes. CAUTION Connect the electrical connection to the starting motor. For Non-Cummins® branded starters, refer to the OEM service manual for torque specifications.
Finishing Steps WARNING Batteries can emit explosive gases. To reduce the possibility of personal injury, always ventilate the compartment before servicing the batteries. To reduce the possibility of arcing, remove the negative (-) battery cable first and attach the negative (-) battery cable last. Connect the batteries. Refer to the OEM service manual. Operate the starter to check for proper function.