Cummins — 4021531

Electronic Controlled Fuel System QSB4.5 and QSB6.7 Page 1-12 Section 1 - Operating Instructions The fault code will flash in the following sequence: First, a WARNING (yellow) lamp will flash. Then there will be a short 1- or 2-second pause, after which the number of the recorded fault code will flash in STOP (red) lamp. There will be a 1- or 2-second pause between each number. When the number has finished flashing in red, a yellow lamp will appear again. The three-digit code will repeat in the same sequence. The lights flash each fault code out two times before advancing to the next code.

To skip to the next fault code sooner, move the idle speed adjust switch, if equipped momentarily to the "(+)" position. The previous fault code can be accessed by momentarily moving the idle speed adjust switch, if equipped to the "(-)" position. If only one active fault is recorded, the control system will continuously display the same fault code, even when either the "(+)" or "(-)" switch is depressed. The explanation and correction of the fault codes are explained in Section TF in the ISB, ISBe2, ISBe3, ISBe4, QSB4.5, QSB5.9, QSB6.7, ISC, QSC8.3, ISL, ISLe3, ISLe4, and QSL9 CM850 Electronic Control System Troubleshooting and Repair Manual, Bulletin Number 4021416.

When not using the diagnostic system, turn off the diagnostic switch, or remove the shorting plug. If the diagnostic switch is left on or the shorting plug in, the ECM will not log some faults.