Cummins — 4021531

Crankcase Breather Tube QSB4.5 and QSB6.7 Page 3-2 Section 3 - Maintenance Procedures at Daily Interval Air Tanks and Reservoirs Drain If automatic purging or spitter valves are used, confirm the valves are operating correctly. If a manual drain valve is used on the wet tank, open the draincock on the wet tank to drain any moisture accumulated in the air system. If oil is present, the air compressor system must be checked. Contact your Cummins Authorized Repair Location. Crankcase Breather Tube Maintenance Check Inspect the breather tube for sludge, debris, or ice in the tube. Inspect the tube more frequently in icy conditions.

If sludge, debris, or ice is found clean the tube with detergent and warm water or a solvent. Dry the tube with compressed air. Visually inspect the tube for cracks or damage. If damage is found, replace the crankcase breather tube. Contact your Cummins Authorized Repair Location.