Cummins — 4021531

QSB4.5 and QSB6.7 Fuel-Water Separator Section 3 - Maintenance Procedures at Daily Interval Page 3-3 Fuel-Water Separator Drain Drain the water-fuel separator into a container and dispose of in accordance with local environmental regulations. WARNING Cummins Inc. requires a fuel-water separator or fuel filter be installed in the fuel supply system. Drain the water and sediment from the separator daily. Canister Type Shut off the engine. Pull up on the drain valve lever until fluid drains out of the drain tube. Drain the filter sump until clear fuel is visible. Push up on the drain valve until fluid drains out of the drain tube. Spin-on Type Shut off the engine.

Use your hand to open the drain valve. Turn the valve counterclockwise approximately 3Ѕ turns until the valve drops down 25.4mm [1 in] and draining occurs. Drain the filter sump until clear fuel is visible. When closing the drain valve, do not overtighten the valve. Overtightening can damage the threads. CAUTION To close the valve, lift the valve and turn clockwise until it is hand-tight.