Cummins — 4021531

Charge-Air Cooler QSB4.5 and QSB6.7 Page 4-2 Section 4 - Maintenance Procedures at 250 Hours or 3 Months Industrial Gas Mechanical Indicator A mechanical restriction indicator is available to indicate excessive air restriction through a dry-type air cleaner. This instrument is mounted in the air cleaner outlet. The red flag (1) in the window gradually rises as the cartridge loads with dirt. When air restriction is indicated the air filter must be replaced. After changing or replacing the cartridge, reset the indicator by pushing the reset button (2) Air Compressor Maintenance Check NOTE: Depending on the application, it is possible engines will not be equipped with an air compressor.

Inspect the compressor housing for cracks and damage. Inspect the hydraulic pump couplings for cracks, wear, or other damage, if equipped. Inspect the air plumbing for splits or cracks. Inspect the air compressor mounting nuts, including support bracket, for loose or damaged hardware. Operate the engine and check for correct compressor operation. Check for air, oil, and coolant leaks. Torque Value: Mounting 18 mm Step 1 77 N•m [ 57 ft-lb ] Torque Value: Bracket 10 mm Step 1 45 N•m [ 33 ft-lb ] Charge-Air Cooler Maintenance Check Inspect the charge-air cooler (CAC) for dirt and debris blocking the fins. Check for cracks, holes, or other damage.

If damage is found, refer to the vehicle, vessel, or equipment manufacturer.