QSB4.5 and QSB6.7 Fan, Cooling Section 4 - Maintenance Procedures at 250 Hours or 3 Months Page 4-3 Charge-Air Piping Maintenance Check Inspect the charge-air piping and hoses for leaks, holes, cracks, or loose connections. Tighten the hose clamps if necessary. Refer to the vehicle or equipment manufacturer's specifications for the correct torque value. Radiator Hoses Maintenance Check Check all hoses for cracks, cuts, or collapsing. NOTE: The silicone engine coolant hose will exhibit swelling due to the elasticity of the hose. If damage is found, replace damaged hoses. Contact your local Cummins Authorized Repair Location.
Air Intake Piping Maintenance Check Inspect the intake piping daily for wear points and damage to piping, loose clamps, and punctures that can damage the engine. Replace damaged pipes and tighten loose clamps, as necessary, to prevent the air system from leaking. Check for corrosion under the clamps and hoses of the intake system piping. Corrosion can allow corrosive products and dirt to enter the intake system. Disassemble and clean, as required. Torque Value: 8 N•m [ 71 in-lb ] Fan, Cooling Inspect for Reuse Do not rotate the engine by pulling or prying on the fan. The fan blade(s) can be damaged and cause the fan to fail and cause personal injury or property damage.
Use the accessory drive shaft or the crankshaft barring tool to rotate the crankshaft. WARNING