Komatsu — 24.2 WHEN REQUIRED

24. SERVICE PROCEDURE 24.2 WHEN REQUIRED WARNING Be sure to put a warning tag on work equipment control levers 1 . 24.2.1 CHECK, CLEAN, OR REPLACE AIR CLEANER ELEMENT WARNING Never clean or replace the air cleaner element with the engine running. When using pressure air to clean the element wear safety glasses or goggles to protect the eyes. CHECKING If air cleaner clogging caution lamp 1 on the maintenance monitor flashes, clean the air cleaner element. NOTICE Do not clean the air cleaner element before the air cleaner clogging portion pilot lamps (Right and left) flash.

If the air cleaner element is cleaned frequently before the air cleaner clogging portion pilot lamps (Right and left) flash, the proper performance of the air cleaner is not provided and the cleaning efficiency is lowered. In addition, dust sticking to the cleaner element falls on the inner element side while cleaning the element. CLEANING OR REPLACING OUTER ELEMENT 1. Remove wing nut 2 , then take out outer element 3 . 2. Clean the inside of the air cleaner body. 3. Direct dry compressed air (less than 0.69 MPa (7 kgf/cm 2 , 99.4 PSI)), to the element from inside along its folds, then direct it from outside along its folds and again from inside.

1) Remove one seal from the outer element whenever the outer element has been cleaned. 2) Replace the outer element which has been cleaned 6 times repeatedly or used throughout a year. Replace the inner element at the same time. 3) If the dust indicator flashes immediately after the outer element has been cleaned, replace both inner and outer elements, even if the outer element has not been cleaned 6 times. 4) Check inner element mounting nuts for looseness and, if necessary, retighten. 5) Replace seal washer 4 or nut 2 with new parts if they are broken. AE063670 3-22