24. SERVICE PROCEDURE NOTICE If small holes or thinner parts are found on element when it is checked with an electric bulb after cleaning and drying, replace the element. When cleaning the element, do not hit it or beat it against anything. Do not use element whose folds or gasket or seal are damaged. AE063690 4. Install the cleaned outer element 3 . REPLACING INNER ELEMENT 1. First remove the outer element, and then remove the inner element. 2. To prevent dust from getting in, use a clean cloth or tape to cover the air connector (outlet side). 3. Clean the air cleaner body interior, then remove the cover installed in Step 2. 4.
Fit a new inner element to the connector and tighten it with nuts. Do not clean and reinstall an inner element. 5. Install the outer element. 3-23