24. SERVICE PROCEDURE 24.2.17 BLEEDING AIR FROM HYDRAULIC TANK After replacing oil and filter element or cleaning strainer, bleed the air from the circuit. When changing the oil in the hydraulic tank, or removing the piston pump, or removing the piping of the piston pump, bleed the air in the following way after assembling. After bleeding air from piston pump, bleed air from hydraulic circuit. Bleeding air from piston pump NOTICE If the air is not bleed completely, the piston pump may be damaged, so always carry out the air bleeding operation correctly. Before bleeding the air from the piston pump, check that the hydraulic oil in the hydraulic tank is filled to the specified level.
The cap of the hydraulic tank remains removing, until the air bleeding of the piston pump finishes. 1. Loosen plug 1 on top of the tube at the suction side of the piston pump. There is one plug for each pump, so loosen all plugs (3 places). 2. Continue until oil flows out from plug 1 (3 places). After the air has been completely bled, tighten plug 1 (3 places). After that, in order to fill the inside of the pump with the hydraulic oil, leave it is for 10 minutes. 3. Check the oil level and add oil if necessary. 4. Fix the cap of the hydraulic tank filler port. 5. Loosen the mouthpiece of the case drain hose 2 , starting an engine at the condition of low idling.
Tighten the mouthpiece, confirming that hydraulic oil flows from the mouthpiece. For details, contact your Komatsu distributor. 3-40