24. SERVICE PROCEDURE Bleeding air from hydraulic circuit. 1. Check that the oil reaches the specified level in the hydraulic tank. 2. Run the engine at low idling and operate each hydraulic cylin- ders (of steering, bucket and lift arm) 4 to 5 times, stopping 100 mm (3.94 in) from stroke end. 3. Next, operate each cylinder 3 to 4 times to the end of its stroke, then stop the engine and loosen air bleeding plug 1 of the hydraulic tank to bleed the air. After bleeding the air, tighten the plug. 4. Check the hydraulic oil level and add oil if necessary, Refer to “24.5 EVERY 100 HOURS SERVICE”. 5.
Increase the engine speed, and repeat step 3 to bleed the air until no more bubbles come out from plug 1 . If the engine is run at high speed at first, or if the cylinder is moved to the end of its stroke, the air in the cylinder may damage the piston packing, etc. 6. After bleeding the air, tighten the air bleeding plug 1 . Tightening torque of the plug: 11.28 ± 1.47 N·m (1.15 ± 0.15 kgf·m, 8.32 ± 1.08 lbft) 7. Check the oil level in the hydraulic tank, and add oil if necessary. After adding oil, tighten the oil filler cap securely. 8. Check the hydraulic oil level and ensure that is correct, Refer to “24.5 EVERY 100 HOURS SERVICE”. 3-41