MID 128-SID 211 MID 128-SID 211 MID 128 SID 211 — SENSOR SUPPLY VOLTAGE #2 FMI 4 Voltage Below Normal, or Shorted To Low Source Failure Mode Identifier (FMI): 3 (Voltage Above Normal, or Shorted To High Source), 4 (Voltage Below Normal, or Shorted To Low Source) Possible causes: 5 volt reference circuit shorted to ground Faulty harness or connector Parameter Identification (PID): S211 Faulty sensor power supply Message Identification (MID): 128 MID 128 PID's 27, 94, 100, 153 and 362 may also be set Circuit Description: This fault code is used to detect a short circuit in the 5 volt supply to the Fuel Pressure Sensor, Crankcase Pressure Sensor and the Oil Pressure Sensor.
Reaction from Engine Management System (EMS) Module: MIL lamp illuminated Location: Internal to the Engine Management System (EMS) Module. Noticeable external symptoms: FMI 3 Strange information displayed on cluster Poor driveability Voltage Above Normal, or Shorted To High Source Possible causes: 5 volt reference circuit shorted to positive Faulty harness or connector Faulty sensor power supply MID 128 PID's 27, 94, 100, 153 and 362 may also be set Reaction from Engine Management System (EMS) Module: MIL lamp illuminated Noticeable external symptoms: Strange information displayed on cluster Poor driveability Page 119 MID 128-SID 211