Mack Trucks V-MAC IV — Mack Trucks V-MAC IV — спецификация (EN)

MID 140-PID 118 MID 140-PID 118 MID 140 PID 118 — SECONDARY AIR PRESSURE TRANSDUCER FMI 4 Voltage Below Normal, or Shorted To Low Source Failure Mode Identifier (FMI): 3 (Voltage Above Normal, or Shorted To High Source), 4 (Voltage Below Normal, or Shorted To Low Source) Conditions for fault code: Abnormally low voltage Voltage below .25 volts Parameter Identification (PID): P118 Possible causes: Faulty harness Message Identification (MID): 140 Faulty sensor Circuit Description: N/A Location: N/A Reaction from Vehicle Electronic Control Unit (VECU): FMI 3 Electronic malfunction lamp is illuminated Noticeable external symptoms:

Voltage Above Normal, or Shorted To High Source Gauge needle moves to zero position Conditions for fault code: Abnormally high voltage Voltage above 5.0 volts Possible causes: Faulty harness Faulty sensor Reaction from Vehicle Electronic Control Unit (VECU): Electronic malfunction lamp is illuminated Noticeable external symptoms: Gauge needle moves to zero position Page 129 MID 140-PID 118