Mack Trucks V-MAC IV — Mack Trucks V-MAC IV — спецификация (EN)

MID 140-PID 170 MID 140-PID 170 MID 140 PID 170 — INTERIOR TEMPERATURE FMI 6 Current Above Normal or Grounded Circuit Failure Mode Identifier (FMI): 5 (Current Below Normal or Open Circuit), 6 (Current Above Normal or Grounded Circuit) Conditions for fault code: Circuit shorted to ground Sensor resistance below 140 Ohm Parameter Identification (PID): P170 Message Identification (MID): 140 Possible causes: Faulty harness Circuit Description: The temperature sensor is a thermistor. The resistance of the sensor changes inversely to the temperature of the interior air. When the temperature is cold, the sensor resistance is high.

As the temperature of the interior increases, the sensor resistance decreases. The Instrument Cluster Module (ICM) monitors the voltage drop across the temperature sensor. Faulty sensor Reaction from Instrument Cluster Module (ICM): Electronic malfunction lamp is illuminated Noticeable external symptoms: Gauge needle moves to zero position Location: N/A FMI 5 Current Below Normal or Open Circuit Conditions for fault code: Open circuit Sensor resistance above 38 kOhm Possible causes: Faulty harness Faulty sensor Reaction from Instrument Cluster Module (ICM): Electronic malfunction lamp is illuminated Noticeable external symptoms: Gauge needle moves to zero position Page 130 MID 140-PID 170