MID 144-PID 191 MID 144-PID 191 MID 144 PID 191 — OUTPUT SHAFT SPEED FMI 6 Current Above Normal or Grounded Circuit Failure Mode Identifier (FMI): 5 (Current Below Normal or Open Circuit), 6 (Current Above Normal or Grounded Circuit) Conditions for fault code: Possible causes: Parameter Identification (PID): P191 Faulty harness Message Identification (MID): 144 Faulty Output Shaft Speed (OSS) sensor Faulty Vehicle Speed Sensor (VSS) Circuit Description: The vehicle speed sensor circuit is open or shorted to ground. Reaction from Vehicle Electronic Control Unit (VECU): Location: The Output Shaft Speed (OSS) sensor is located at the rear of the transmission. N/A Noticeable external symptoms:
FMI 5 NA Current Below Normal or Open Circuit Conditions for fault code: Abnormally low current Possible causes: Faulty harness Faulty Output Shaft Speed (OSS) sensor Faulty Vehicle Speed Sensor (VSS) Reaction from Vehicle Electronic Control Unit (VECU): N/A Noticeable external symptoms: NA Page 154 MID 144-PID 191