MID 144-PPID 3 MID 144-PPID 3 MID 144 PPID 3 — STARTER OUTPUT FMI 4 Voltage Below Normal, or Shorted To Low Source Failure Mode Identifier (FMI): 3 (Voltage Above Normal, or Shorted To High Source), 4 (Voltage Below Normal, or Shorted To Low Source) Conditions for fault code: Abnormally low voltage Short circuit to ground Parameter Identification (PID): P3 Output not activated, key not in starter motor position Message Identification (MID): 144 Circuit Description: There is abnormally high voltage or a short circuit to a higher voltage. There may also be a abnormally low voltage or short circuit to ground. Possible causes: Faulty harness or cables Starter circuit relay Location:
The starter motor is located on the side of the engine. Reaction from Vehicle Electronic Control Unit (VECU): FMI 3 Red lamp is illuminated Speaker signal sounds Voltage Above Normal, or Shorted To High Source Noticeable external symptoms: Conditions for fault code: Starter motor does not activate when requested Abnormally high voltage Short circuit to a higher voltage Excessively high current through the drive state Possible causes: Faulty harness or cables Starter circuit relay Reaction from Vehicle Electronic Control Unit (VECU): Red lamp is illuminated Speaker signal sounds Noticeable external symptoms: Starter motor does not activate when requested Page 155 MID 144-PPID 3