Mack Trucks V-MAC IV — Mack Trucks V-MAC IV — спецификация (EN)

MID 144-PPID 69 MID 144-PPID 69 MID 144 PPID 69 — BUFFERED IDLE VALIDATION SWITCH FMI 4 Voltage Below Normal, or Shorted To Low Source Failure Mode Identifier (FMI): 3 (Voltage Above Normal, or Shorted To High Source), 4 (Voltage Below Normal, or Shorted To Low Source) Conditions for fault code: Abnormally low voltage or short to ground Buffered IVS1 too low compared to IVS1 signal Parameter Identification (PPID): P69 Message Identification (MID): 144 Possible causes: Circuit Description: The Idle Validation Switch (IVS) updates the Vehicle Electronic Control Unit (VECU) with the idle status. At idle, the Idle Validation Switch (IVS) is open and no voltage is applied.

At approximately 5% - 100% pedal position the Idle Validation Switch (IVS) closes. Signal shorted low Faulty harness Reaction from Vehicle Electronic Control Unit (VECU): Location: The Idle Validation Switch is integral to the Accelerator Pedal Position (APP) Sensor. The Accelerator Pedal Position (APP) Sensor is part of the accelerator pedal assembly. Yellow lamp is illuminated Noticeable external symptoms: N/A FMI 3 Voltage Above Normal, or Shorted To High Source Conditions for fault code: Abnormally high voltage or short to higher voltage Buffered IVS1 too high compared to IVS1 signal Possible causes: Signal shorted high Faulty harness Reaction from Vehicle Electronic Control Unit (VECU):

Yellow lamp is illuminated Noticeable external symptoms: N/A Page 158 MID 144-PPID 69